Eliminates eliminate manganese installment

Introduces our country to have many local places to deliver a letter, the iron and the manganese content were high, surpass or have surpassed the life tap water sanitation standard and the process water standard greatly. The ferri, manganese Shui Youtie t

share


Introduces our country to have many local places to deliver a letter, the iron and the manganese content were high, surpass or have surpassed the life tap water sanitation standard and the process water standard greatly. The ferri, manganese Shui Youtie the fishy smell, in the use can produce the brown rusty stain on each kind of household wares, washes clothes to be able to dye the yellow or the yellowish brown dirt, precipitates ferroguinous may make the iron bacteria in the pipeline endophragm to grow, causes the water cock to emit “the red water”; The ferri (manganese) the water uses in the papermaking, the textile film manufacture or the leather making and so on, may cause the product to produce the stain, is unable to improve the product quality. In order to adapt the life tap water and the process water need, the development use ferri (manganese) the groundwater resources, this company in Scientific research Unit's under and so on Tongji University cooperation, developed novel, the highly effective integration to eliminate the iron (manganese) the equipment - - ZNFMY(Z) series to eliminate the iron to eliminate the manganese water clarifier.
      The ZNFMY(Z) series eliminated the iron to eliminate the manganese water clarifier to use the newest technology “the active biomembrane contact oxo-process”, because this product technical process was simple, eliminated the iron to eliminate the manganese not to throw adds any medicament, had the movement stably reliable, to be strong to the water quality serviceability, processing efficiency high, economic efficiency remarkable and so on characteristics, was eliminates the iron to eliminate the manganese the ideal equipment. the ZNFMY(Z) series except the iron except manganese water purification principle in the ground water the iron and the manganese by two price condition existence, this equipment's water purification main principle is generally: After ferri (manganese) underground Water Classic aeration, in the water the iron (manganese) starts to oxidize, when current of water after manganese ore or specially made quartz sand filter bed filtration, because filters the material the chemical action and filters the material surface the iron (manganese) the bacterium (multi-gemma rust-fungus, ferri fine ferrobacillus, single cell iron bacteria and rust color throw over trichobacteria and so on) the biochemical action, in filters in the material level to start to have functions and so on biochemical reaction, catalytic oxidation response and physical interception adsorption, these process's combined action may speed up in greatly the water the iron (manganese) oxidation, solidification and elimination, thus achieves anticipated effect.
     Technical process in 1. local sewer ferri density in 5-10mg/L, including manganese density when 1-2mg/L, when or in ground water only ferri not including manganese, when about ferri density 10mg/L, may use the aeration - - single stage to eliminate the iron to eliminate the manganese filter technical process: deep well - - deep well pump - - oxygenizement aeration - - except iron except manganese water clarifier - - water tank (or basin) 2., if in the ground water the iron, the manganese content are high time, namely the iron is bigger than 10mg/L, the manganese is bigger than when 2.0mg/L, uses the aeration - - two-stage to eliminate the iron suitably to eliminate the manganese technical process: the deep well - - forcing pump - - oxygenizement aeration - - first-level eliminates the iron to eliminate the manganese water clarifier - - basin (or water tank) the 3. single stage pressure type eliminates the iron to eliminate manganese water clarifier technical process schematic drawing the 4. single stage gravity type to eliminate the iron to eliminate manganese water clarifier technical process schematic drawing the ZNFMY(Z) series to eliminate the iron to eliminate manganese water clarifier main performance 

型号

公(gōng)稱直徑
D(㎜)

反沖洗強度
L/m2·S

處理(lǐ)能(néng)力
m3/h

設備荷重
T

ZNFMY-5

1000

15

5

6.2

ZNFMY-10

1200

15

10

7.5

ZNFMY-15

1500

15

15

10.2

ZNFMY-20

1600

15

20

12.4

ZNFMY-30

2000

15

30

18.5

ZNFMY-40

2400

15

40

28.2

ZNFMY-50

2600

15

50

33.7

ZNFMY-100

3600

15

100

68.6

ZNFMY-150

4400

15

150

103

ZNFMY-200

5100

15

200

144

ZNFMY-250

5800

15

250

173


Eliminates eliminate manganese installment
Introduces our country to have many local places to deliver a letter, the iron and the manganese content were high, surpass or have surpassed the life tap water sanitation standard and the process water standard greatly. The ferri, manganese Shui Youtie t
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

Jiangsu Chensheng Environmental Protection Technology Co., Ltd.

Address: Jiangsu Yixing Central Branch Park Street Fukang Road
                  No.26

Tel:0510-87020033、87020032 

   0510-87137555、87137558 

Fax:0510-87137556 

E-Mail:web@chenshengep.com 

    jscshb@126.com 

Website:www.chenshengep.com 

Copying(C)2017-2018Jiangsu Chensheng Environmental Protection Technology Co., Ltd All Rights Reserved.

添加微信好友,詳細了解産(chǎn)品
使用(yòng)企業微信
“掃一掃”加入群聊
複制成功
添加微信好友,詳細了解産(chǎn)品
我知道了